17 resultados para Fruta de clima temperado

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

(The Mark and Recapture Network: a Heliconius case study). The current pace of habitat destruction, especially in tropical landscapes, has increased the need for understanding minimum patch requirements and patch distance as tools for conserving species in forest remnants. Mark recapture and tagging studies have been instrumental in providing parameters for functional models. Because of their popularity, ease of manipulation and well known biology, butterflies have become model in studies of spatial structure. Yet, most studies on butterflies movement have focused on temperate species that live in open habitats, in which forest patches are barrier to movement. This study aimed to view and review data from mark-recapture as a network in two species of butterfly (Heliconius erato and Heliconius melpomene). A work of marking and recapture of the species was carried out in an Atlantic forest reserve located about 20km from the city of Natal (RN). Mark recapture studies were conducted in 3 weekly visits during January-February and July-August in 2007 and 2008. Captures were more common in two sections of the dirt road, with minimal collection in the forest trail. The spatial spread of captures was similar in the two species. Yet, distances between recaptures seem to be greater for Heliconius erato than for Heliconius melpomene. In addition, the erato network is more disconnected, suggesting that this specie has shorter traveling patches. Moving on to the network, both species have similar number of links (N) and unweighed vertices (L). However, melpomene has a weighed network 50% more connections than erato. These network metrics suggest that erato has more compartmentalized network and restricted movement than melpomene. Thus, erato has a larger number of disconnected components, nC, in the network, and a smaller network diameter. The frequency distribution of network connectivity for both species was better explained by a Power-law than by a random, Poissom distribution, showing that the Power-law provides a better fit than the Poisson for both species. Moreover, the Powerlaw erato is much better adjusted than in melpomene, which should be linked to the small movements that erato makes in the network

Relevância:

80.00% 80.00%

Publicador:

Resumo:

(The Mark and Recapture Network: a Heliconius case study). The current pace of habitat destruction, especially in tropical landscapes, has increased the need for understanding minimum patch requirements and patch distance as tools for conserving species in forest remnants. Mark recapture and tagging studies have been instrumental in providing parameters for functional models. Because of their popularity, ease of manipulation and well known biology, butterflies have become model in studies of spatial structure. Yet, most studies on butterflies movement have focused on temperate species that live in open habitats, in which forest patches are barrier to movement. This study aimed to view and review data from mark-recapture as a network in two species of butterfly (Heliconius erato and Heliconius melpomene). A work of marking and recapture of the species was carried out in an Atlantic forest reserve located about 20km from the city of Natal (RN). Mark recapture studies were conducted in 3 weekly visits during January-February and July-August in 2007 and 2008. Captures were more common in two sections of the dirt road, with minimal collection in the forest trail. The spatial spread of captures was similar in the two species. Yet, distances between recaptures seem to be greater for Heliconius erato than for Heliconius melpomene. In addition, the erato network is more disconnected, suggesting that this specie has shorter traveling patches. Moving on to the network, both species have similar number of links (N) and unweighed vertices (L). However, melpomene has a weighed network 50% more connections than erato. These network metrics suggest that erato has more compartmentalized network and restricted movement than melpomene. Thus, erato has a larger number of disconnected components, nC, in the network, and a smaller network diameter. The frequency distribution of network connectivity for both species was better explained by a Power-law than by a random, Poissom distribution, showing that the Power-law provides a better fit than the Poisson for both species. Moreover, the Powerlaw erato is much better adjusted than in melpomene, which should be linked to the small movements that erato makes in the network

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to investigate if exist relationship between organizational culture and the organizational climate, having as research s locus three dairy industries in the Rio Grande do Norte State. As such, an exploratory-descriptive and conclusive-causal study, with a sample composed of 211 employees of all firms hierarchical levels was undertaken. By way the data collection, the employees personal characteristics, the predominant organizational culture profile and the predominant organizational climate in the industries researched were identified. In order to analyse the organizational culture, the Competing Value Model (CAMERON; QUINN, 2006), with adaptations by Santos (1998, 2000), was used. In order to analyse the organizational climate, the Organizational Climate Measurement Scale, proposed by Martins (et al., 2004, 2008), with modifications, was used. The data were submitted to quantitative statistical analyses, firstly to the set of firms and afterwards to the firms alone, that permitted arrival to the following conclusions: the cultural profiles was met in a balanced way in the researched organizations, with emphasis to clan culture and market culture profiles; the researched organizations have a good organizational climate, based in the Martins (2008) classification, with emphasis to boss and organization s support and physical comfort , being these factors coherent whit the clan culture profile; the personal variables are correlated with the cultural profiles and with the organizational climate factors, however, each organization show its singular form of relation; and the cultural profiles showed influence on organizational climate factors. Thus, the results permitted to conclude that there are relations between the cultural profiles and the organizational climate factors in the researched organizations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research consists in studying the influence of the various type of construction systems of roofs with their energy efficiency as well as on the cost benefit for the commercial buildings on the temperatures condition of the city of Natal/RN. The main goal of this research is to analyze the cost benefit of the construction systems of roofs available on the market, taking into consideration the energy efficiency of the commercial buildings artificially air conditioned in order to be used by the projectors and to be adequated to the temperatures condition of the city of Natal/RN. The method of valuation of the cost benefit of roof systems consists in six steps: Features and simulation of the reference building; Analyze of sensitivity; Analyzes, features and simulation of alternatives of roof construction systems; Analyze of the cost of implementation; Analyze of the benefits of the alternatives comparing to the base case; And finally the analyze of the cost benefit. The model type chosen as reference was stores with pre molded buildings and system of roof with fiber ciment and ceiling . The thermal results showed the influence of the roof system on the energy efficiency of the building. The Final results of the simulations of the alternatives comes to a conclusion that the absortance is the variable that presents the best cost benefit relation and the reduction on the thermal transmittance still has limitations because of the high cost

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of building thermal performance is often carried out using HVAC energy consumption data, when available, or thermal comfort variables measurements, for free-running buildings. Both types of data can be determined by monitoring or computer simulation. The assessment based on thermal comfort variables is the most complex because it depends on the determination of the thermal comfort zone. For these reasons, this master thesis explores methods of building thermal performance assessment using variables of thermal comfort simulated by DesignBuilder software. The main objective is to contribute to the development of methods to support architectural decisions during the design process, and energy and sustainable rating systems. The research method consists on selecting thermal comfort methods, modeling them in electronic sheets with output charts developed to optimize the analyses, which are used to assess the simulation results of low cost house configurations. The house models consist in a base case, which are already built, and changes in thermal transmittance, absorptance, and shading. The simulation results are assessed using each thermal comfort method, to identify the sensitivity of them. The final results show the limitations of the methods, the importance of a method that considers thermal radiance and wind speed, and the contribution of the chart proposed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study deals with the relationship between urban vegetation and climate. The process whereby the Parque das Dunas a 1,172 ha green area in the city of Natal, State of Rio Grande do Norte exerts influence on the climate of the city is analyzed. The hypothesis on which the present work rests is that the green area referred to acts upon the climate of the city. The study is based on the analysis of climatic factors and elements of this green area and of the city of Natal. In order to give rise to final recommendations, a methodology grounded on a quantitative and qualitative standpoint has been used. The data were collected both within and without the limits of the Parque das Dunas area. Secondary and primary data resulting from the measurements taken by the researcher and her work group have been used. The aim was to contribute to the understanding of the influence of vegetation on the climate of a city having a warm and humid climate. A historical and environmental characterization of the Parque das Dunas was then sought. The local climatic factors and the elements of the climate have been studied within the scope of the city of Natal. A comparative study between the climatic elements within and without the limits of the Parque das Dunas area from the survey of technical data and the systematization of the information collected has been made, aiming at proposing a set of bioclimatic recommendations for the urban design in Natal. The results of such work allowed for the validation of the important role that the Parque das Dunas plays in the climate of Natal. This has led to the acknowledgement of the relevance of the green areas on the climate of cities. They bring about important benefits to the process of rendering agreeable the climate in the urban environment by providing pleasant microclimates that give a valuable contribution to the environmental comfort of urban nuclei having the same size of Natal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natural air ventilation is the most import passive strategy to provide thermal comfort in hot and humid climates and a significant low energy strategy. However, the natural ventilated building requires more attention with the architectural design than a conventional building with air conditioning systems, and the results are less reliable. Therefore, this thesis focuses on softwares and methods to predict the natural ventilation performance from the point of view of the architect, with limited resource and knowledge of fluid mechanics. A typical prefabricated building was modelled due to its simplified geometry, low cost and occurrence at the local campus. Firstly, the study emphasized the use of computational fluid dynamics (CFD) software, to simulate the air flow outside and inside the building. A series of approaches were developed to make the simulations possible, compromising the results fidelity. Secondly, the results of CFD simulations were used as the input of an energy tool, to simulate the thermal performance under different rates of air renew. Thirdly, the results of temperature were assessed in terms of thermal comfort. Complementary simulations were carried out to detail the analyses. The results show the potentialities of these tools. However the discussions concerning the simplifications of the approaches, the limitations of the tools and the level of knowledge of the average architect are the major contribution of this study

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This master thesis aims to assess the influence of the design decisions on the energy building performance of hotels. The research is based on the integration of field study and computer simulation. Firstly, a detailed field study is carried out to identify the characteristics of hotels in Natal, Rio Grande do Norte. The items assessed are occupancies, light and equipment densities, types of air conditioning, total and monthly energy consumption, among others. A second and more comprehensive field study is carried out to identify the range of occurrence of architectural variables, with a larger number of buildings. A base case is modelled in VisualDOE, based on the first field study. Then, a first set of simulations are run to explore the sensitivity of the variables on the energy consumption. The results analyses were the base of a second set of simulations, which combined the most influential variables. The results of 384 models were assessed, and the impacts of design decisions were quantified. The study discusses tendencies and recommendations, as well as the methods advantages and disadvantages

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Hospital Epidemiology Nucleus (NHE) is a structure that has a specific organizational climate, which influence the level of job satisfaction among professionals working in it. This is a descriptive study with a quantitative approach, aimed to identify the relationship between organizational climate in the NHE regulated in the city of Natal / RN and the job satisfaction among its professionals from the perspective of theoretical issues about Organizational Development. The research was carried out in 13 hospitals with different kinds of sponsorship, 9 public, 3 philanthropic and 1 private. Data were collected using the instrument "organization in hospitals: issues relating to climate and job satisfaction , with 33 professionals appointed and active on NHE. This study obtained an appropriate consent of the Research Ethics Committee of the Hospital of Pediatrics Professor Heriberto Ferreira Bezerra, from the Riograndense Northern League Against Cancer and the Federal University of Rio Grande do Norte. Data collected were organized and treated with simple descriptive statistics. It was observed that from 33 of surveyed people, 93% was female, had an average of 40 years old age, with activity duration between 1 and 2 years (84.9%). Furthermore, 45.5% of industry professionals were nurses. It was identified that professionals working in NHE perceive and experience its work environment as an Organization Structure in construction. It was found that with the exception of the aspects "working life", "socio-cultural" and "organizational culture , the other internal and external factors to the NHE does not have strong expression in the forming of an organizational climate conducive to the development of the sector. It was found that 70% of interviewed perceive the organizational climate as favorable for the industry's progress. Regarding the job level of satisfaction, respondents feel fairly satisfied with the organizational structure. Therefore, the results of this study are suggestive that there is some factor that is greatly contributing to a healthy organizational climate that encourages the industry team members of the NHE present behaviors that identify them as actors committed and satisfied with the work, even face of all obstacles to implementation of epidemiological surveillance. Thus, it is suggested for futures studies to seek to determine how the organizational culture, while significant internal factor, influencing the organizational climate establishment of NHE and therefore the level of job satisfaction and well-being of each members of the team

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the publication of the report "To Err is Human" by the Institute of Medicine (IOM) , which estimated that between 44.000 to 98.000 Americans die annually as a result of errors in health care, patient safety spent gaining prominence, emerging studies assess the safety culture by measuring the safety climate. In this context, the aim of this study was to identify safety culture perceived by nursing professionals working in the intensive care unit of a maternity school in Natal/RN through the Security Attitudes Questionnaire (SAQ). This was a descriptive study, cross-sectional and quantitative approach undertaken in the Intensive Care Unit Maternal and Neonatal a maternity school in Natal/RN. The project was submitted to and approved by Brazil Platform Zip/UFRN under number 309 540 and CAAE 16489713.7.0000.5537. It was used to collect data two instruments: a questionnaire in order to collect socio-demographic data of the subjects and the Questionário Atitudes de Segurança , a cultural adaptation to Portuguese of the instrument of the World Health Organization titled Safety Attitudes Questionnaire - (SAQ ) Short Form 2006. The collected data were analyzed quantitatively by the organization in electronic databases in Microsoft Excel 2010 spreadsheet and exported to statistical software for free access to be coded, tabulated and analyzed using descriptive statistics. The study included a total of 50 nurses, 31 and 19 of the NICU Maternal ICU, predominantly female, mean age 35 years, median time of 10 years training and working in maternity, mostly, less than 05 anos. As a result, two articles were produced. The first refers to the first two domains of the instrument entitled "climate of teamwork" and "climate security" . The scores of the two areas were slightly higher in Maternal ICU compared to the NICU, but no sector has reached the ideal minimum score of 75: in the first domain Maternal ICU had an average of 74.77, with medians of 75 and 100, while Neonatal ICU reached an average of 69.61 with median also 75 and 100, while the second field means were 69.35 and 66.01 for Maternal and Neonatal ICUs respectively, with a median of 100 in the two sectors. The second article relates to the field "Perception Management Unit and Hospital", which 9 assessed the perception of management units and motherhood by professionals. In general, the items of the domain in question also obtained scores below the ideal minimum: 63.68 to 51.02 and maternal ICU for neonatal, featuring a clear separation between the management and the professionals who work in direct care. These findings indicate a warning sign for the institution and point to the need to implement actions aimed at patient safety

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The knowledge of Anastrepha zenildae behavioral aspects combined with the biology of Tephritidae may contribute to monitoring and control programs of this fruit fly that is considered as economically important to the Rio Grande do Norte state. In order to characterize the daily activity profile of this species, we studied the behaviors of resting, locomotion, feeding, cleaning, courtship, copulation and oviposition of animals submitted to an artificial 12:12h light-dark cycle (750:1lux) with controlled temperature (26±2 °C). The observations were made with groups of 16 males and 16 females during 3 consecutive days each generation from parental to F5. Resting, locomotion, feeding and cleaning data were recorded as frequency and time of occurrence by scanning technique in 15 minutes windows per hour, with a record each minute. Courtship, copulation and oviposition were recorded as frequency, time of occurrence and duration by al occurrences technique. Resting was the most frequent behavior with males resting more than females. Locomotion was more evident in the first half of the ligh phase with higher values in females. Cleaning and feeding behaviors were more frequent in the second half of the light phase for both sexes with females eating more frequently than males. During the courtship, males were grouped in lek formations showing wings vibration and pheromone liberation. Courtship occurred more frequently 4 to 7 h after lights on (81,9%) with copulations being more frequent 6 h after lights on with a mean duration of 58,1±40,4 min. Copulation attempts were observed in males inside and outside the lek with aggressive behavior being observed only between males in the lek. Oviposition behavior was similar to that described for other species of the genus with a peak of this activity 2-3 h after the lights on, mean duration of 43, 7±34, 8 sec and 2 to 5 eggs by event. According to the results, sexual behavior of A. zenildae is temporally different of other sympatric species of the genus, being favorable to the reproductive isolation as well as the use of resources as oviposition substrate.